Logo

POLES

No Length
(mm)
Top
(mm)
Bottom
(mm)
Design
Load(kN)
Safety
Factor,K
Total
Holes
Pole
Weight(kgs)
1 9 160 260 2 2.5 35   670
2 9 190 310 5 2.5 35   825
3 9 230 350 8 2.5 35   1,222
4 12 190 350 3 2.5 48   1,054
5 12 230 390 6 2.5 4   1,444
6 12 270 430 9 2.5 48   1,738
7 14 190 376 4 2.5 46   1,352
8 14 230 416 6.5 2.5 46   1,646

Phnom Penh Precast Plants produces pre-stressed concrete spun poles including but not limited to the following:


All our RC spun poles meet EDC strict specification. Our poles have a safety factor of 2.5 as specified by EDC. Our factory has a base capacity of “10± poles” per hour. We are able to produce “80± base poles” per shift. We can increase shift and/or hours in a shift to meet project needs. We can produce custom poles to customer’s needs up to 14 meters in length and 3 tons in weight. Provide us your specifications and our team will design the optimal pole.

PILES

PHC Piles Class A
No Outer
Diameter
(mm)
Length
(m)
Wall
Thickness
(mm)
Concrete
Strength
(Mpa)
Crack
Moment
(Mcr)
Allowable axial
load tf.m (kN.m)
Weight
(kg)
1 300 6 60 80 2.49 113.78   770
2 300 8 60 80 2.49 113.78   1,036
3 300 9 60 80 2.49 113.78   1,120
4 300 10 60 80 2.49 113.78   1,223
5 300 11 60 80 2.49 113.78   1,370
6 300 12 60 80 2.49 113.78   1,485
7 350 6 65 80 3.82 146.35   993
8 350 8 65 80 3.82 146.35   1,276
9 350 9 65 80 3.82 146.35   1,401
10 350 10 65 80 3.82 146.35   1,551
11 350 11 65 80 3.82 146.35   1,701
12 350 12 65 80 3.82 146.35   1,895
13 400 6 75 80 5.79 192.44   1,332
14 400 8 75 80 5.79 192.44   1,658
15 400 9 75 80 5.79 192.44   1,882
16 400 10 75 80 5.79 192.44   2,120
17 400 11 75 80 5.79 192.44   2,324
18 400 12 75 80 5.79 192.44   2,458

Phnom Penh Precast Plants produces pre-stressed concrete spun piles including but not limited to the following:


Our PC / PHC class A spun piles have a base capacity of “12± piles” per hour. PHC pile specifications provide on request. Our company is able to produce “96± piles” per shift. We can increase shift and /or hours in a shift to meet project needs. Piles can be produced up to 400mm in diameter and 12m in length. Provide us your specification and our team will help you design the optimal pile.

PIPES

No Diameter
(mm)
Length
(m)
Wall Thickness
(mm)
Weight of Pipe
(kg)
1 600 2.50 80   1,135
2 800 2.50 100   1,905
3 1,000 2.50 100   2,420
4 1,200 2.50 120   3,342
5 1,500 2.50 140   4,590

Phnom Penh Precast Plants produces pipes including but not limited to the following:


Our pipes can meet the ASTMC76M, DIN 4035, and JIS standards. We are a member of ACPA ( American Concrete Pipe Association). Our reinforced concrete vibration pipes have a base capacity of “5± pipes” per hour. For base pipes our company is able to produce “40± pipes”per shift. We can increase shifts and / or hours in a shift to meet project needs. Provide us your specification and our team will help you design the optimal pipe.